Technical Articles
Grid Coupling Technical Guides
Grid couplings carry torque through a serpentine steel spring, the grid, that runs in the grooves of two hubs. Under load the grid flexes, so shock is cushioned and torsional vibration drops before it reaches the motor or gearbox. Belt conveyors, crushers and induced-draft fans are the usual drives.
We make the JS series to JB/T 8869-2000, including brake disc (JSP), brake wheel (JSZ) and intermediate shaft (JSA) versions. A worn grid can be bought on its own. Without a drawing, send photos of the coupling, grid and cover. Add both bore diameters and the outside diameter, and we draw it up for you to approve.
Belt Conveyor Coupling Selection: 7 Engineering Checks
Start with the conveyor duty, not with a coupling model or motor power alone.
Mining Crusher Coupling: How to Handle Shock Loads
A crusher does not see one steady load. Rock impact, uneven feed, blocked chambers, hard starts, reversing and emergency stops can all…
Grid or Gear Couplings for Crushers and Conveyors?
When the priority is to reduce the effect of startup, reversing, or material impact on the gearbox, first evaluate a Grid Coupling.
Grid vs Pin Bush Coupling for Conveyors: Guide
Neither coupling is universally better. A Grid Coupling is often evaluated when the conveyor has loaded starts, impact or torsional…
Cement Conveyor Coupling Selection: Dust, Start-Up Torque, and Service Factor
A cement conveyor coupling should be selected for loaded starts, dust, intermittent blockage, and the actual reducer output torque.
Grid Coupling Spring Failure on Ball Mill Drives: Frozen-Charge Shock, Lubrication or Misalignment?
A broken grid spring on a ball mill drive leaves clear evidence. This guide shows how to read fracture faces, groove wear and grease to…
Grid Coupling Maintenance Checklist for Paper Machine Auxiliary Drives: Grid, Grease and Cover
A practical grid coupling maintenance checklist for paper machine auxiliary drives: isolation, inspection order, early warning signs…