Technical Articles
Technical Articles - Page 6
Jaw Coupling Spider Failure on Rolling Mill Hydraulic Power Units: Causes and Checks
When jaw coupling spiders melt, crumble or crack on rolling mill hydraulic power units, the cause is usually in the drive. This guide…
Replacement Jaw Coupling Spiders and Hubs for Pickling and Galvanizing Line Pumps: What to Match
Original imported jaw couplings on pickling and galvanizing line pumps and fans can be replaced without long waits for original spares.…
How to Install a Jaw Coupling on Cement Plant Rotary Valves and Screw Conveyors: Gap, Set Screws, Alignment
Most early jaw coupling failures on cement plant rotary valves and screw conveyors come from assembly. This guide covers pre-installation…
Rigid Coupling Bolts Loosening on Cooling Bed Line Shafts: Alignment, Bearing Settlement and Preload Checks
Bolts that keep loosening or breaking on one rigid coupling of a cooling bed line shaft usually point to the shaft line, not the bolts.…
Curved Jaw vs Straight Jaw Coupling for Mine Dewatering Pumps: Which One Fits?
Curved jaw (star) and straight jaw couplings both suit mine dewatering and concentrator pumps, but they differ in pre-compression…
Gantry Travel Drive Pin Gear Couplings on Port Cranes: Replace the Pins or the Whole Coupling?
Gantry travel drive pin gear couplings on port cranes tend to wear in batches. This guide shows how to measure and record wear, when new…
Jaw Coupling Spider Melting Next to the Brake Wheel on Steel Plant Crane Drives: Brake Drag, Runout or Duty?
A jaw coupling spider that melts on the brake-wheel side, with a blue brake wheel, points to a heat problem in the brake system. This…
Changing Jaw Coupling Spiders Without Moving the Motor: LMS Double-Flange Retrofit on Caster Cooling Water Pumps
On caster cooling water pumps, every spider change on a basic jaw coupling means moving and realigning the motor. This guide explains how…
Jaw Coupling Hub Cracked on a Concentrator Agitator? Loaded Starts, Hub Material and Bore Fit
A cracked hub or broken jaw on an agitator jaw coupling usually traces back to loaded restarts, brittle hub material or a bad fit. This…
How to Remove a Seized Jaw Coupling Hub in a Salt-Air Port, and Refit It So It Comes Off Next Time
Salt air can lock a jaw coupling hub onto its shaft on port equipment. This guide shows how to prepare and pull a seized hub without…
Tyre Coupling Element Replacement on Cement Plant Separators and Fans: Split Tyres, Bolt Tightening and Storage
Changing a tyre coupling element on cement plant separators and fans goes wrong mostly at the clamping faces and bolts. This guide covers…
Roller Chain Coupling Maintenance on Sinter Plant Feeders: Chain Elongation, Sprocket Wear and Grease in Dust
Roller chain couplings on sinter plant feeders wear through chain elongation and hooked sprocket teeth, sped up by ore and flux dust. This…